FLIR LEPTONĀ® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
8
Figure 1. Lepton with shutter Camera (with and without socket)
1.4 Device Overview
Lepton is an infrared camera system that integrates a fixed-focus lens assembly, an 80x60 or 160x120 long-wave
infrared (LWIR) microbolometer sensor array, and signal-processing electronics. Some configurations are also
provided with an integral shutter assembly that is used to automatically optimize image uniformity on a periodic
basis. Easy to integrate and operate, Lepton is intended for mobile devices as well as any other application
requiring very small footprint, very low power, and instant-on operation. Lepton can be operated in its default
mode or configured into other modes through a command and control interface (CCI).
Figure 1 shows a view of the Lepton with Radiometry camera as standalone and mounted in a socket.