8 Technical specifications
Accuracy specifications for all measurement ranges are applicable under the fol-
lowing ambient conditions: 18 to 28 (64.4 to 82.4); <80% RH.
8.1 General specifications
Display
3-digit 15 mm (0.6″) main display
4-digit 6 mm (0.24″) secondary
display
10-segment bar graph
Memory counter
Controls
7 dedicated function buttons:
moisture, relative humidity, con-
densation, hold/lock, up (⇑), down
(⇓), store/recall
4 auxiliary buttons: IR, Bluetooth,
backlight/work light, power
Other indications
24 icon-style locations + 2-digit
memory indicator
Piezo beeper (85 dBA)
Sample rate 2 per second
Backlight White LED
Internal memory (1) storage location
Power supply 1 × 9 V battery (MN1604 or
equivalent)
Battery life 100 hours, using alkaline batteries,
with no backlight/work light use
Auto power off (APO) After 30 minutes (nominal) inactivity,
with audible pre-alert; reset when the
power button is pressed. Disable
function supported
APO quiescent current
50 µA maximum
#T559822; r. AE/ 10036/10036; en-US 41