EasyManua.ls Logo

Flomec TM Series - Wiring; Wiring Connections and Features

Flomec TM Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
GETTING STARTED
OPERATION /
CALIBRATION
SAFETY /
SPECIFICATIONS
ASSEMBLY /
INSTALLATION
MAINTENANCE /
REPAIR
MAINTENANCE
NOTE: Proper handling and care will extend the life and service of the meter
Turbine Rotor
The meter is virtually maintenance-free. However, it is important the rotor moves freely.
Keep the meter clean and free of contaminants.
If the rotor does not turn freely, apply a penetrating lubricant on the rotor, shaft and bearings.
Remove any debris or deposits from the rotor using a soft brush or small probe. Be careful
not to damage the turbine rotor or supports.
Blowing compressed air through the turbine assembly
could damage the rotor.
Do not allow liquids to dry inside the turbine.
Handle the rotor carefully. Small scratches or nicks can
affect accuracy.

Other manuals for Flomec TM Series

Related product manuals