Module shown installed on G2 1” stainless steel flowmeter
4-20mA MODULE
FOR USE WITH MOST* FLOMEC TURBINE METERS
WITH Q9 DISPLAY
*FLOMEC QSE meters have their own 4-20mA module
09/2021 920907-01 Rev. C
Product
Owners
Manual
EN
NN

Other manuals for Flomec TM Series

Questions and Answers:

Flomec TM Series Specifications

General IconGeneral
TypeTurbine Flow Meter
ModelTM Series
Repeatability±0.1% of reading
OutputPulse, 4-20mA
MaterialStainless Steel
Measurement Range0.1 to 1000 LPM
Operating Temperature-40°F to +250°F (-40°C to +121°C)
Materials of Construction316 Stainless Steel

Summary

Before You Begin

Usage Requirements

Key usage requirements for the 4-20mA module, including power and compatibility.

Unpacking and Inspection

Steps for inspecting the unit after unpacking for damage and checking parts.

Specifications

Mechanical, Power, and Output Specs

Details on mechanical aspects, power, primary output (4-20mA), and scaled pulse output.

Temperature Limits

Ambient and Fluid Temperature Graph

Graph and notes on ambient and fluid temperature limits for the module.

Approval Ratings

Installation

Installing the Module

Step-by-step instructions for installing the 4-20mA module onto the flowmeter.

Wiring

Wiring Connections and Features

Details on wire colors, features, and connection diagrams for the 4-20mA module.

Wiring Options and Configuration

Explanation of internal and external options for pull-up resistance and voltage selection.

Operation and Calibration

Adjusting Zero and Span

Guidance on setting and adjusting ZERO and SPAN using the Q9 Owner's Manual.

Troubleshooting

No Output Signal Issues

Lists symptoms, causes, and corrective actions for when there is no output signal.

Signal Out of Range Issues

Addresses issues with the signal not being within the 4-20mA range during flow.

Pulse Output Not Working

Troubleshooting steps for issues with the scaled pulse output feature not functioning.

Inaccurate Pulse Output Volumes

Solutions for inaccurate pulse output values related to total volumes.

Incorrect Flowrate Display

Troubleshooting for incorrect flowrate readings displayed on the Q9 unit.

Incorrect Volume Totals Display

Troubleshooting for incorrect volume total readings displayed on the Q9 unit.

Parts List

Parts and Service

WEEE Directive

Two-Year Limited Warranty

Related product manuals