IPS Detect
Page 12 of 35
OIM_FLS_IPS Detect_EN_14
Subject to technical changes! FLOWSERVE
5.1.1 Configuration vibration velocity
Measurement of the vibration velocity (RMS) enables the condition of the pump to be
determined. This gives an indication of the Mechanical wear within the pump unit.
Examples for causes of high vibration velocity:
Mechanical wear
Imbalance
Misalignment
Excessive force from the pipe-work
Vibration Velocity Settings:
Parameter standard setting possible setting
Measuring range [mm/s] 0...10 1.) 0...10
2.) 0...20
Warning LED [mm/s] 3,5 0...20
Failure LED [mm/s] 4,5 0...20
Changes to the standard values can be saved and loaded onto the sensor through the use
will be displayed in the configuration software.