Flowserve.com 9 PUIOM000650-00-UIM (EN/HL) August 2022
SEM-100 and SEM-100FT User Instructions
3.4 Materials of construction
The SEM-100 and SEM-100FT electronic ow meters are resistant to
corrosion from typical ag-chem and light industrial chemicals. Wetted
materials include:
• Fluid Housing/Form Cover ------- Nylon or Polypropylene
• Meter Chamber ------- Polypropylene Sulde (PPS),
Stainless Steel
• O-rings ------- Viton or EPDM
• Electronic Housing ------- Nylon
• Screws ------- Stainless Steel
Note: The Polypropylene SEM-100 and SEM-100FT meters are designed
to pump chemicals with a low PH. Ensure chemical compatibility between
liquid metered and the meter’s wetted parts before using
Note: Meter should not be used to transfer ammable petroleum products.
DO NOT use with uids that have a ashpoint lower than 37°C (100°F).
Refer to the Scienco Product Reference Manual FPD-1607 to learn
more about the available congurations.