EasyManua.ls Logo

flsun SR - Page 26

Default Icon
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Q6 Solutions when display errors
Error: TH-MAX The nozzle temperature sensor short circuit, please check the nozzle
temperature sensor or the nozzle temperature sensor connector.
Error: TB-MAX The hot-bed temperature sensor short circuit, please check the hot-bed
temperature sensor or the hot-bed temperature sensor connector
Error: TH-MIN The nozzle temperature sensor broken circuit, please check the nozzle
temperature sensor or the nozzle temperature sensor connector.
Error: TB-MIN The hot-bed temperature sensor broken circuit, please check the hot-bed
temperature sensor or the hot-bed temperature sensor connector.
Error: TH-Runaway The temperature sensor at the nozzle fails or is suddenly
disconnected during printing.
Error: Heating failed The nozzle temperature sensor fails or suddenly disconnects during
preheating or heating.
Q7 The printer can’t be levelled, and the three axes don’t go home.
Solution 1: Click “Set>Restore”, and then do the Auto-Levelling again.
Solution 2: Check whether the red light on the limit switch is on. If the light on the limit
switch is not on, it may be that the limit switch is damaged. Swap with other limit switch
and try again.