4. Press the ▲ button to
make the required
selection.
The selection US GAL
shows.
For the explanation,
the measurement unit for the
(accumulated) total is set to
US GAL.
5. Press the PROG button
momentarily.
The PROG indicator
goes off.
The selection is
confirmed.
The Flowmeter (K-factor) unit m
3
is
automatically converted to show the
total in US Gallons.
6. Press the ▲ button until
the DECIMALS menu
shows.
The DECIMALS menu
shows.
7. Press the PROG button
momentarily.
The PROG indicator
comes on.
Now you can set the decimal
pointer for display purposes only.
8. Press the ▲ button to
make the required
selection.
The selection 0.1 shows.
For the explanation,
the decimals for the (accumulated)
total are set to 1 decimal.
9. Press the PROG button
momentarily.
The PROG indicator
goes off.
The selection is
confirmed.
The K-factor and the K-factor decimals for the (accumulated) total shows as
AUTO because the automatic unit conversion controls these parameters.
If 7 digits is not sufficient to show the (accumulated) total, you can multiply the
reading by x10, x100, etc. This multiplication factor is set in the next menu.
10. Press the ▲ button until
the FACTOR X menu
shows.
The FACTOR X menu
shows.
11. Press the PROG button
momentarily.
The PROG indicator
comes on.
Now you can set the multiplication
factor for the (accumulated) total
which require more than 7 digits.
12. Press the ▲ button to
make the required
selection.
The selection 10 shows.
For the explanation,
the multiplication factor for the
(accumulated) total.is set to 10x.
13. Press the PROG button
momentarily.
The PROG indicator
goes off.
The selection is
confirmed.