Electrical Multimeter
International Electrical Symbols
3
International Electrical Symbols
Table 1 lists the international symbols that appear in this document and on the Meter.
Table 1. Electrical Symbols
Symbol Description Symbol Description
B AC (Alternating Current) I Fuse
F DC (Direct Current) T Double Insulated
X Hazardous voltage W Important Information; Refer to manual
N Battery (Low battery when shown on the
display.)
J Earth ground
~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
Specifications
Accuracy is specified for 1 year after calibration at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. Extended
specifications are available at www.fluke.com.
General Specifications
Maximum voltage between any
terminal and earth ground ................................... 600 V
Surge Protection................................................... 6 kV peak per IEC 61010-1 600V CAT III,
Pollution Degree 2
Display ................................................................... Digital: 3¾-digits, 6,000 counts, updates 4/sec
Temperature .......................................................... Operating: -10 °C to 50 °C (14 °F to 122 °F)
Storage: -40 °C to 60 °C (-22 °F to 140 °F)
Temperature Coefficient ...................................... 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Operating Altitude ................................................ 2,000 meters
Storage Altitude .................................................... 10,000 meters
Battery ................................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6F22
Battery Life ............................................................ Alkaline: 300 hours typical, without backlight
Shock ..................................................................... 1 Meter drop per IEC 61010-1-2001
Vibration ................................................................ Per MIL-PRF-28800 for Class 2 instrument
Size......................................................................... 6.58 in X 3.35 in X 1.81 in (167.1 mm X 85.1 mm X 46.0 mm)
Weight .................................................................... 13.0 oz (404 g)
Safety Compliances.............................................. Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL
6101-1 (2004) and IEC/EN 61010-1 2
nd
Edition for measurement Category III, 600 V, Pollution
Degree 2, EMC EN61326-1
EMI Regulations .................................................... Complies with FCC Part 15, Class B
Certifications ......................................................... UL, P, CSA, TÜV, ; (N10140), VDE