Technical DataTechnical Data
Power quality that meets the standard:
All measurements comply with IEC61000-4-30
standards for correct evaluation of all measured
values including voltage, current, power, har-
monics, flicker etc.
Quick and reliable configuration: PDA wire-
less “front panel interface” provides the ability
to verify setup without a laptop along with a
window into what the instrument is recording,
even in awkward test locations.
Threshold-free setup: Apply thresholds after
data is collected with Fluke Power Analyze
Software so there is no need to worry about
missed information due to incorrect set-up.
Captures everything: Cross-channel and current
triggering capture every measurement, on every
channel, every time.
Capture every measurement, every event,
on every cycle, all the time with the Fluke
1750 Power Recorder. Outstanding accuracy
and resolution provide complete visibility into
your installation or distribution system.
Fluke 1750
Three-Phase Power Recorder
Never miss capturing a
disturbancewith the exclusive
threshold-free measurement
system, it’s automatic.
Intuitive PC software: Easily analyze data and
generate reports. Automated EN50160 reporting
and compliance.
Plug and play: Set up in minutes with self-
identifying current probes and single-lead voltage
connections.
No need to reconnect wires: Swap channels
internally with the wireless PDA or PC when
connections are not correct.
Measure every parameter: voltage and current
on three phases, neutral, and ground.
5 MHz, 8000 Vpk waveform capture: Get a
detailed picture of even the shortest events.
Quickly retrieve data: With included SD memory
card or via the 100BaseT high-speed Ethernet
connection.

Other manuals for Fluke 1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1750 and is the answer not in the manual?

Fluke 1750 Specifications

General IconGeneral
TypePower Quality Analyzer
Frequency Measurement Range42.5 Hz to 69 Hz
Safety RatingCAT IV 600 V, CAT III 1000 V
Accuracy±0.1% of reading
HarmonicsUp to 50th harmonic
CommunicationEthernet, USB
Power Supply100 V to 240 V AC
Channels4 voltage, 4 current
Battery BackupYes, internal battery
Measurement ParametersVoltage, Current, Power, Harmonics, Flicker
Data Logging Interval1 second to 60 minutes
Battery Life45 minutes (UPS)
Voltage Measurement Range1 to 1000 V (phase to neutral)
Operating Temperature-10 to 50 °C