Page #7 background image
Multimeters
Safe Working Practices
3
Use only current probes, test leads, and
adapters supplied with the Product.
Connect the common test lead before
the live test lead and remove the live test
lead before the common test lead.
Keep fingers behind the finger guards on
the probes.
Only use probes, test leads, and
accessories that have the same
measurement category, voltage, and
amperage ratings as the Product.
Remove all probes, test leads, and
accessories before the battery door is
opened.
Do not exceed the Measurement
Category (CAT) rating of the lowest rated
individual component of a Product,
probe, or accessory.

Other manuals for Fluke 17B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 17B and is the answer not in the manual?

Fluke 17B Specifications

General IconGeneral
ContinuityYes
Diode TestYes
AC Current400μA / 4000μA / 40mA / 400mA / 4A / 10A
Display4000 counts
Duty Cycle0.1% to 99.9%
Safety RatingCAT III 600V, CAT II 1000V
Resistance400Ω / 4kΩ / 40kΩ / 400kΩ / 4MΩ / 40MΩ