EasyManua.ls Logo

Fluke 289 - AC Current Specifications

Fluke 289
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
True-rms Digital Multimeters
Detailed Specifications
69
AC Current Specifications
Accuracy
Function Range Resolution
20 to 45 Hz 45 to 1 kHz 1 to 20 kHz 20 to 100 kHz
[4]
500 μA 0.01 μA
1 % + 20 0.6 % + 20 0.6 % + 20 5 % + 40
AC μA
[3]
5000 μA 0.1 μA
1 % + 5 0.6 % + 5 0.6 % + 10 5 % + 40
50 mA 0.001 mA 1 % + 20 0.6 % + 20 0.6 % + 20 5 % + 40 AC mA
[3]
400 mA 0.01 mA 1 % + 5 0.6 % + 5 1.5 % + 10 5 % + 40
5 A 0.0001 A 1.5 % + 20 0.8 % + 20 3 % + 40
[4]
Not Spec’d AC A
[2]
10 A
[1]
0.001 A 1.5 % + 5 0.8 % + 5 3 % + 10
[4]
Not Spec’d
[1] 10 A range (10 % to 100 % of range).
[2] 20 A for 30 seconds on, 10 minutes off. >10 A not specified.
[3] 400 mA continuous; 550 mA for 2 minutes on, 1 minute off.
[4] Verified by design and type tests.
See Detailed Specifications introduction for additional information.

Table of Contents