AC Leakage Current Clamp
Maintenance
5
Environmental Specifications
Operating temperature ......................... -10 °C to +50 °C
Storage temperature ............................. -40 °C to +60 °C
Operating humidity
(without condensation) ........................ Non condensing (<10 °C)
90 % RH (10 °C to 30 °C)
75 % RH (30 °C to 40 °C)
45 % RH (40 °C to 50 °C)
Ingress Protection ................................ IEC 60529: IP30 with jaw closed
Operating Altitude ................................. 2,000 m
Storage Altitude .................................... 12,000 m
Current Sensor Operating Class ......... IEC 61557-13: Class 2, 30 A/m
Radio Frequency Certification
(FC Units Only) ...................................... FCC ID:T68-FBLE IC:6627A-FBLE
Wireless Radio Frequency Range ....... 2412 MHz to 2462 MHz
Output Power ........................................ <100 mW
Radio Frequency Data .......................... Search for “Radio Frequency Data for Class A” (PN 4333628) on the Fluke
website.
Electromagnetic Compatibility (EMC)
International .................................. IEC 61326-1: Industrial Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is
necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low
voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) ................................... Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should
take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) ...................................... 47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
Safety Specifications
Safety
General ............................................. IEC61010-1: Pollution degree 2
Measurement .................................... IEC61010-2-032: CAT III 600V
Maintenance
If the Product does not work or perform properly, use these steps to help isolate
the problem:
1. Inspect the jaw mating surface for cleanliness. If any foreign material is
present, the jaw will not close properly and measurement errors will result.
2. Verify that the range on the Product is correct.