Specifications
AC Current
Range ..................................................... 600.0 A
Resolution...............................................0.1 A
Accuracy .................................................2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz) ..........................2.5 @ 600 A
AC Voltage
Range .................................................... 600.0 V
Resolution...............................................0.1 V
Accuracy .................................................1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range .................................................... 600.0 V
Resolution...............................................0.1 V
Accuracy
[1]
...............................................1 % ± 5 digits
[1]
in an RF field greater than 1 V/m between 130 MHz and 350 MHz, add 65
counts to specified accuracy.
Resistance
Range ..................................................... 600.0 Ω/6000 Ω
Resolution...............................................0.1 Ω/1 Ω
Accuracy .................................................1 % ± 5 digits
Continuity Beeper ................................... 30 Ω
Capacitance
Range .................................................... 10.0 – 100.0 μF / 1000 μF
Resolution...............................................0.1 μF/1 μF
Accuracy .................................................1.9 % ± 2 digits