374 FC/375 FC/376 FC
Users Manual
24
Temperature Coefficients........................ Add 0.1 x specified accuracy for each degree C above
28 °C or below 18 °C
AC Current via Jaw
Range
374 FC and 375 FC ........................... 600.0 A
376 FC ............................................... 999.9 A
Resolution ............................................... 0.1 A
Accuracy ................................................. 2 % ±5 digits (10 Hz to 100 Hz)
2.5 % ±5 digits (100 to 500 Hz)
Crest Factor (50 Hz/60 Hz)
376 FC .............................................. 3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
374 FC and 375 FC .......................... 2.5 @ 350 A
1.42 @ 600 A
Note: Add 2 % for C.F. >2