6100B/6105A
Users Manual
5-22
Keyword Parameter Form Notes
:HARMonic<y> <dnpd>,<dnpd> <y> is harmonic number.
<dnpd> = Amplitude, Phase.
Note: amplitude absolute or %
depending on value of
UNIT:MHAR:...
:AMPLitude(?) <dnpd> Absolute or %
:PANGle(?) <dnpd>
:HARMonic<y>? [<cpd> {AMPLitude | PANGle}]
:ALL? [<cpd> {AMPLitude | PANGle}] Response is in csv format.
:FHARmonics
[:STATe](?) <bool>{OFF|ON|0|1}
:CLEar
:FLUCtuate<y>(?) <bool>{OFF|ON|0|1} <y> is harmonic number.
:ALL? Response in csv format.
:MODulation <dnpd>,<dnpd> <dnpd> = Depth, Frequency.
:MODulation? [<cpd>{ DEPTh | FREQuency }]
:SHAPe(?) <cpd>{ RECTangular | SINusoidal | SQUare}
:DUTY(?) <dnpd>
:IHARmonics
[:STATe](?) <bool>{OFF|ON|0|1}
:SIGNal<y> <bool>{OFF|ON|0|1}[,<dnpd>,<dnpd>] <y> = signal (1 or 2).
<dnpd> = Amplitude, Frequency.
:SIGNal<y>? [<cpd>{ STATe | AMPLitude | FREQuency }]
:DIP
[:STATe](?) <bool>{OFF|ON|0|1}
:ENVelope <dnpd>,<dnpd>,<dnpd>,<dnpd>,<dnpd> <dnpd> =
Change to,
Ramp in,
Duration,
Ramp out,
End Delay
:ENVelope? [<cpd>{CHANge | RIN | DURation | ROUT |
EDELay}]
:TRIGger
:INPut(?) <cpd>{ FREE | EONE | EREPeat}
:ODELay(?) <dnpd>
:HOLDoff(?) <cpd>{ PHASe | DELay },<dnpd> <dnpd> units depends on the <cpd>.
:REPeat (?) <dnpd>
:FLICker
[:STATe](?) <bool> { OFF | ON | 0 | 1 }
:FREQuency(?) <dnpd>
:UNIT(?) <cpd> { HZ | CPM }
:DEPTh(?) <dnpd>
:PINSt?
:PST?