EasyManua.ls Logo

Fluke 6200-2 - Memory; Save Test Results; Clear Memory

Fluke 6200-2
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appliance Tester
Memory
19
Memory
The Tester has a non-volatile memory to save a minimum of 100 test results. The power-on
screen shows a message if the memory is full or nearly full:
> 75 Internal memory is nearly full (>75 %)
> Internal memory is completely full
If one of these messages is shown you should print the stored test results (see Print Test
Results) and then clear the store.
Save Test Results
Note
The test continues to save the result while in the continuous test mode.
To save a test result to memory, push . The display shows the number that has been
assigned to the record for 2 seconds, for example 5, then:
it reverts to the idle screen if a test was finished.
in the continuous test mode, it shows the next result.
If you push again while the record number shows, the result will not be stored.
If you store a result in the continuous test mode during the test, the displayed result is stored
without a test interruption.
If you push in the continuous test mode before a new result is available, the display
shows 0 and the beeper sounds twice.
If the result cannot be saved because the memory is full, you must clear the memory, repeat
the test, and then store the result.
Clear Memory
The clear function clears all memory locations. It is disabled during any appliance test.
If you want to preserve the results, print the results before you clear the memory.
To clear the memory, hold for more than 5 seconds. The display shows the progress. If a
double beep sounds, the clear action was incomplete.

Related product manuals