RTD Calibrator
Specifications
29
Ohms Source
Ohms Range
Excitation Current from
Measurement Device
Accuracy
(% of Output + Floor)
1 year 2 year
1.0 to 400.0 0.1 mA to 0.5 mA 0.015 % + 0.1 0.03 % + 0.2
1.00 to 400.00 0.5 mA to 3 mA 0.015 % + 0.05 0.03 % + 0.08
400.0 to 1500.0 0.05 mA to 0.8 mA 0.015 % + 0.5 0.03 % + 0.8
1500.0 to 4000.0 0.05 mA to 0.4 mA 0.015 % + 0.5 0.03 % + 0.8
Resolution
1.00 to 400.00 0.01
400.0 to 4000.0 0.1
Notes:
1) Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.
2) Temperature coefficient: ± (0.002 % of output + 0.002 % of range) /°C ( <18 °C or >28 °C)