Specifications
Electrical Specifications
DC Current Measurement
With Jaw
Ranges ............................................... 0 mA to 20.99 mA;
21 mA to 100 mA
Resolution........................................... 0.01 mA, 0.1 mA
Accuracy ............................................. 0.2 % + 5 counts, 1 % + 5 counts
In Circuit
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
Current Source
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
mA Drive ............................................. 24 mA into 1000 Ω
Current Simulate
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
Maximum Voltage ............................... 50 V
DC Voltage Measurement (773/773-II)
Range ................................................. 0 V to 30 V
Resolution........................................... 0.01 V
Accuracy ............................................. 0.2 % + 2 counts
DC voltage source (773/773-II)
Range ................................................. 0 V to 10 V
Resolution........................................... 0.01 V
Accuracy ............................................. 0.2 % + 2 counts
mA Drive ............................................. 2 mA max all conditions
mA IN/OUT (773/773-II)
Sourcing range ................................... 0 mA to 24 mA