8600
A
(battery power option)
is
configured at the factory
for
115
Vac, or 230 Vac,
50
Hz or
60
Hz line power
operation.
The battery power
option must not
be
operated from any
other line voltage or frequency
than
that for
which it is
configured
(see decal on bottom of case). The
operation
of
the front
panel controls is the same
for
all power configu-
rations of the
8600A, 8600A-01, and 8600A-02 instruments.
1-9.
SPECIFICATIONS
1-10.
Specifications
for
the Model
8600A are presented
in Table
1-3, under
headings of DC
VOLTAGE, AC VOLTAGE,
DC
CURRENT,
AC CURRENT,
OHMS, and GENERAL.
Specifications for each
option
are listed under the
option
heading.
Table 1-3.
MODEL
8600A
SPECIFICATIONS
DC VOLTAGE
Ranges
+200
mV, +2V,+20V,+200V, +
1200V
Accuracy
:
6
Months (15°C
to
35°C)
200 mV range
2V,
20V, and 200V ranges
. .
1200V range
Temperature
Coefficient:
200 mV range
2V
to 1200V ranges
....
Input
Impedance:
+(0.001?'o
of input +0.0005%
of range)/°C
200 mV
and 2V ranges
. .
.
20V, 200V and
1200V
ranges
10
megohms
Normal Mode Rejection
.
.
.
60
dB
minimum @
50
Hz,
60
Hz
Common Mode Rejection
. . .
either
lead)
Zero Stability
Ranging
Polarity
Automatic bipolar,
+
or
display
Overload +
1200V dc
or
1700V peak ac
applied
continuously
to
any
range.
Response Time
to
Rated
Accuracy Within Range
. . 1
second maximum
to
displayed
input
AC VOLTAGE
Ranges
200 mV, 2V, 20V, 200V, 1200V
Accuracy
:
6
Months (15°Cto
35°C)
200 mV range
(100%
to 1%
of range)
30 Hz
-
50
Hz; +(0.5% of input
+0.10% of
range)
50 Hz
-
10
kHz;
±(0.2%
of input +0.08% of
range)
10
kHz
-
50
kHz;
+(0.5%
of
input
+
0.10%
of
range)
50
kHz
-
100
kHz; +
(0.5%
of input +
0.5%
of range)
2V,
20V and
200V ranges
. .
(100% to 1%
of range)
50
Hz
-
10
kHz;
+(0.2%
of input
+
0.015% of
range)
30 Hz
-
50
Hz and 10 kHz
-
50
kHz;
±(0.5%
of input
+
0.025%
of range)
50
kHz
-
100
kHz;
±(1.0%
of
input
+
0.05%
of range)
1-2
1/77

Table of Contents

Related product manuals