Fluke 8600A - 6-59. BATTERY PACK, OPTION -01

Fluke 8600A
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8600A
6-50.
HIGH
FREQUENCY
PROBE
(81RF)
6-51.
Introduction
6-52.
The
Model
81RF High
Frequency
Probe,
Figure
6-13,
extends
the
frequency
range
of the
8600A to include
100
kHz to
100
MHz for
ac voltage
measurements
from
0.25
to
30V rms.
The
8
1
RF
operates
in
conjunction
with
the
dc voltage
range,
and is
connected
to
the
8600A
using
a
shielded
dual-banana
plug and
an
adapter.
Figure 6-13.
HIGH
FREQUENCY
PROBE
(81RF)
6-53.
Specifications
Transfer
Accuracy
:
Voltage
Range:
Maximum
DC
Input:
Input
Impedance:
±1
dB from
100
kHz
to 100 MHz
.25V rms
to 30V
rms
(operated
into
a 10
M£2 input
resistance
voltmeter).
Peak
responding
calibrated
to read
rms value
of
a sine wave.
350V
12MI2
shunted
by
^
15
pf
maximum
6-54.
Operation
6-55.
Use the
following
procedure
for
operating
the
8600A with
the 81RF
probe:
a.
Connect
the
81RF
shielded
dual-banana
plug
to
the
8600A
V-f2
and LO
INPUT
terminals.
b.
Attach
the
desired
probe
tip to
the probe
body.
c.
Depress
the
DCV
pushbutton
(FUNCTION)
6-56.
TEMPERATURE
PROBE
(80T-150)
6-57
.
The
Model
80T-150
Temperature
Probe
is
a
self-
contained
temperature-to-voltage
converter. It
is
designed
to
provide
a direct
temperature
reading
on the
display of
any
high
impedance
voltmeter
(1MS2)
capable
of 1
mV
resolution,
and at
least
300
mV
full-scale
readout.
The
probe
can be
configured
to
provide
either
one of two
temperature
displays:
-50
to
+150°C
or
-58
to +300°F.
6-58.
Operating
power
for
the probe
is provided
by an
internal
lithium battery.
Typically,
the
battery
will provide
up to
1
000 hours of
continuous
operation
before, replace-
ment
is necessary.
An on/off
switch
is provided to
conserve
the battery
when not
in use.
6-59.
BATTERY
PACK,
OPTION
-01
6-60.
Introduction
6-6
1
. The Battery
Pack
provides
the
8600A with the
capability of
operating
as
a portable
(battery-operated)
in-
strument. Four
nickle
cadmium
(Ni-cad)
batteries
allow,
typically
8 hours of
portable
operation
before
recharging
is necessary.
The
batteries
are
recharged
by
connecting
the
8600A to
the ac
power
line. If
desired,
the
8600A
can be
operated
during
the
charging
process,
however,
the
charging
time will
be
increased.
d.
Select
the
desired voltage
range.
e.
Connect
the
probe’s ground
lead to
a suitable
ground.
f.
Touch
the
probe
tip
to the
circuit
point to
be
measured.
g.
Observe
the
voltage reading
displayed
in volts
rms
on
the
8600A readout.
6-62.
Specification
6-63.
The
specifications
for the
Battery Pack
are
given
in
Section
1 of this
manual.
6-64.
Operation
CAUTION!
Damage may
result if alkaline,
zinc-carbon,
or
mercury
batteries
are charged
in the
8600A.
1/77
6-9

Table of Contents