Table 33. Execution Error Codes and Descriptions (cont.)
Error Code Error Text Description
-126 Numeric real A floating point (real) numeric parameter value was entered.
Example: SAMP:COUN -13.6
-127 Channel dimension
invalid
One or more entries in a channel list parameter has an invalid
number of dimensions.
-130 Parameter suffix A parameter within the Input Command had the wrong type of
units for the Command Specification. Example
VOLT:DC:RANGE 1A
-137 Invalid header suffix Too many numeric suffices in the input for the specified
command. As an example, valid arguments for the FETCH?
Command are FETCH?, FETCH1?, FETCH2?, and FETCH3?.
If FETCH4? is entered, error 137 will be generated.
-150 Invalid string data The parameters in the Input Command contained an
unmatched single or double quote. Example: DISP:TEXT ‘hello
world”.
-154 String size The length of the entered string exceeds 12 characters.
Example CAL:SEC:CODE “this is an example of a long string”.
-157 Unmatched brackets The parameters in the Input Command contain an unmatched
bracket.
-191 Unknown parameter One or more of the parameters contains an unspecified error.
-192 Too many dimensions Too many dimensions in entry.
-193 No entry There was no entry to get - the index was beyond the end of
the entries.
-200 Generic execution General Execution error has occurred.
-211 Trigger ignored A Group Execute Trigger (GET) or *TRG was received but the
trigger was ignored. Make sure the multimeter is in the wait-for-
trigger state before issuing a trigger, and make sure the correct
trigger source is selected.
-213 Init ignored An INITiate command was received but could not be executed
because a measurement was already in progress. Send a
device clear to halt a measurement in progress and place the
multimeter in the idle state.
-214 Trigger deadlock A trigger deadlock occurs when the trigger source is BUS and
a READ? command is received.
-222 Illegal data value
-223 Too much data A character string was received, but could not be executed
because the string length was more than 12 characters. This
error can be generated by the CALibration:STRing and
DISPlay:TEXT commands.
-227 Invalid function Decibels modifier was applied to an selected function that does
not support decibels.