Frequency Range | 3 Hz to 300 kHz |
---|---|
DC Voltage Range | 100 mV to 1000 V |
AC Voltage Range | 100 mV to 750 V |
Resistance Range | 10 Ω to 1 GΩ |
Continuity | Yes |
Diode Test | Yes |
Temperature Measurement | Yes |
Display | 5.5 digit |
Connectivity | USB, RS-232, GPIB |
DC Current Range | 100 µA to 10 A |
AC Current Range | 100 µA to 10 A |
Frequency Accuracy | 0.01 % |
Capacitance Range | 1 nF to 100 µF |
Display Type | VFD |
Power Supply | 100 V to 240 V |
AC Voltage Accuracy | ±(0.06% + 0.03% of reading) |
Resistance Accuracy | ±(0.01% + 0.001% of reading) |
Defines local vs. remote operation and interface limitations.
Details the available interfaces (RS-232, Ethernet, IEEE-488) and their use.
Describes how to enable or select a remote control port.
Details compliance with IEEE-488.2 and operation as a talker/listener.
Details RS-232 communication and parameter setup.
Explains how to set the RS-232 baud rate through menus.
Describes how to set RS-232 parity and data bits.
Explains how to set RS-232 stop bits.
Details how to set RS-232 flow control.
Explains how to set RS-232 end-of-line characters.
Explains Terminal and Computer modes for RS-232.
Details how to configure the LAN port for remote control.
Explains IP address requirements and DHCP.
Details how to set a static IP address manually.
Explains setting the subnet mask for LAN configuration.
Explains how to set the host name.
Details setting the default gateway IP address.
Explains setting the default socket port.
Explains how to switch between SCPI, Fluke 45, and 8842A command sets.
Guides on performing an installation test for connectivity.
Step-by-step procedure for RS-232 connectivity test.
Procedure to test IEEE-488 connectivity.
Describes how to place the meter in a wait-for-trigger state.
Details three methods for external triggering.
Summarizes SCPI CONFigure commands.
Summarizes SCPI math commands.
Summarizes SCPI MEASure commands.
Continues summary of SCPI MEASure commands.
Summarizes SCPI measurement configuration commands.
Continues summary of SCPI measurement configuration commands.
Summarizes SCPI commands for RS-232.
Summarizes SCPI status reporting commands.
Summarizes SCPI system-related commands.
Summarizes SCPI triggering commands.
Explains how to use the MEASure? command.
Continues explanation of the CONFigure command.
Explains how to use the READ? command.
Explains how to use the INITiate command.
Explains how to use the FETCh? command.
Explains using the SENSe subsystem for configuration.
Explains how to program math functions.
Explains how to program the trigger system.
Details specific trigger commands like INITiate and READ?.
Explains commands related to system functions.
Details function modifier commands.