The Outlet Configuration setting determines which cable pairs are tested and which pair numbers are
assigned to the pairs.
T568A
1 white/green
2 green
3 white/orange
4 blue
5 white/blue
6 orange
7 white/brown
8 brown
12
3
4
T568B
1 white/orange
2 orange
3 white/green
4 blue
5 white/blue
6 green
7 white/brown
8 brown
13
2
4
USOC (1 or 2 Pair)
Token Ring
3 white/orange
4 blue
5 white/blue
6 orange
12
ATM/TP-PMD
Straight
1 white/green
2 green
7 white/brown
8 brown
1
2
ATM/TP-PMD
Crossed
2
1
1
2
7
8
7
8
1
2
white/green
green
white/brown
brown
Ethernet
1 white/orange
2 orange
3 white/green
6 green
3
2