DSP-4000 Series
CableAnalyzer
Users Manual
July 2001, Rev. 1, 5/03
© 2000-2003 Fluke Corporation. All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
®
E
s
t
a
b
l
i
s
h
e
d
1
9
8
1

Table of Contents

Questions and Answers

  • K
    Katie GreeneAug 3, 2025
    What to do if Fluke DSP-4100 Measuring Instruments show 'Wire map: open'?
    • B
      Brandy NealAug 3, 2025
      If your Fluke Measuring Instruments display indicates a 'Wire map: open' error, it means there might be several potential issues. The wires could be connected to the wrong pins at the connector or punchdown blocks, or there could be faulty connections. Cables might be routed to the wrong location, or wires could be broken by stress at connections. A damaged connector or cuts/breaks in the cable itself are also possible causes. To resolve this, inspect the cabling for the suggested fault at the location indicated by the diagnostics display.
  • S
    Shelly ObrienAug 10, 2025
    Why do my Fluke DSP-4100 say 'Wire map: crossed pairs'?
    • E
      Elizabeth MeltonAug 10, 2025
      If your Fluke Measuring Instruments are showing 'Wire map: crossed pairs', it indicates that wires are connected to the wrong pins at connectors or punchdown blocks. It could also be due to a mix of 568A and 568B wiring standards, or crossover cables used where they are not needed. Inspect the cabling for the suggested fault at the location indicated by the diagnostics display.
  • C
    Connie WrightAug 18, 2025
    What to do if Fluke DSP-4100 display 'Wire map: split pair'?
    • M
      Michelle BuckleyAug 18, 2025
      If your Fluke Measuring Instruments display the error 'Wire map: split pair', it means that the wires are connected to the wrong pins at the connector or punchdown blocks. To fix this, inspect the cabling for the suggested fault at the location indicated by the diagnostics display.
  • T
    Tom PerezAug 25, 2025
    How to fix 'Wire map: reversed pairs' on Fluke DSP-4100 Measuring Instruments?
    • M
      Mike NicholsAug 26, 2025
      If your Fluke Measuring Instruments are showing 'Wire map: reversed pairs', it indicates that wires are connected to the wrong pins at connector or punchdown blocks. Inspect the cabling for the suggested fault at the location indicated by the diagnostics display.

Summary

Chapter 1 Introduction

Chapter 2 Getting Started

Safety and Operational Information

Crucial safety precautions and operational guidelines for using the test tool.

Quick Start Guide

Provides immediate instructions for users to begin operating the test tool.

Turning On the Test Tool

Instructions on powering on the test tool and what to expect during startup.

Chapter 3 Autotest

Autotest Procedures

Covers autotests for twisted pair and coaxial cabling, including softkey functions.

Saving and Reporting Autotests

Instructions on saving autotest results and understanding the autotest report format.

Chapter 4 Running Individual Tests

Single Tests for Twisted Pair Cabling

Instructions for running individual tests on twisted pair cabling, including scanning.

HDTDX and HDTDR Analysis

Explains HDTDX for crosstalk and HDTDR for fault location and impedance analysis.

Single Tests for Coaxial Cabling

Instructions for executing single tests on coaxial cabling.

Chapter 5 Viewing and Printing Saved Reports

Chapter 6 Calibrations and Custom Test Standards

Chapter 7 Basic Cabling Testing

Chapter 8 Maintenance and Specifications

Fluke DSP-4100 Specifications

General IconGeneral
TypeCable Analyzer
ModelDSP-4100
ManufacturerFluke Networks
Frequency Range1 MHz to 350 MHz
Accuracy± 0.5 dB
Storage Temperature-20 °C to 60 °C (-4 °F to 140 °F)
Test StandardsTIA/EIA-568-B, ISO/IEC 11801
Supported Cable TypesCategory 5e, Category 6, Category 6A
Measurement ParametersLength, Propagation Delay, Delay Skew, Attenuation, NEXT, Return Loss
DisplayBacklit LCD
PC ConnectivityUSB
Power SourceRechargeable battery
Battery LifeApproximately 8 hours
Test ParametersLength, Propagation Delay, Delay Skew, Resistance, Capacitance, Impedance, Attenuation, NEXT, PSNEXT, ACR-N, PSACR-N, ELFEXT, PSELFEXT, ACR-F, PSACR-F, Return Loss
Operating Temperature0 °C to 45 °C (32 °F to 113 °F)