EasyManua.ls Logo

Fluke DSP-4100 - A-1. Tests Supported by Standard Link Interface Adapters

Fluke DSP-4100
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DSP-4000 Series
Users Manual
A-2
Table A-1. Tests Supported by Standard Link Interface Adapters
Standard or Test
DSP-LIA011
Basic Link
DSP-LIA012 and
DSP-LIA013
Channel
DSP-LIA101
Permanent Link
TIA Cat 3, 5, and 5E Basic and
Permanent Link
X
X
TIA Cat 3, 5, 5E, and 6 Channel X
TIA Cat 6 Permanent Link X
Class E Permanent Link X
TIA TSB-75 MUTO Link
X
XX
ISO11801 Channel Class C, D X
ISO11801 Permanent Link Class C, D XX
ISO Link Class C, D XX X
EN 50173 Class C, D XX X
Aus/NZ Class C and D Basic Link
XX
Aus/NZ Class C and D Channel
X
IEEE 10/100/1000BASE-T X
X
X
TokenRing, All
XX X
TP-PMD
XX X
All coaxial standards
X
1
Impulse noise monitor and tone generator
XX X
Traffic monitoring on twisted pair cable DSP-LIA013
only
Hub port locator and hub port capabilities
test
DSP-LIA013
only
Optical power and loss measurements
using a DSP-FOM Fiber Optic Meter
2
XX X
1. All coaxial testing requires the RJ-45 to BNC adapter.
2. Fiber test standards are supported by optional Fiber Test Adapters.