DSP-4000 Series
Users Manual
8-10
Cable Types Tested
Shielded and unshielded twisted pair (STP and UTP) LAN cabling:
TIA Category 3, 4, 5, 5E, and 6 100 Ω
ISO/IEC Class C and D 100 Ω and 120 Ω
Foil-screened twisted pair cables (ScTP):
TIA Category 3, 4, 5, 5E, and 6 100 Ω
ISO/IEC Class C and D 100 Ω and 120 Ω
Shielded twisted pair cables (STP): 150 Ω
(IBM Type 1, 6, and 9; IBM interface adapter required).
Coaxial cables (connect with the RJ45 to BNC adapter):
Thicknet (10BASE5; adapter required)
Thinnet (10BASE2)
RG-58, RG-58 foam, RG-59, RG-59 foam, RG-8, RG-8A/U, and RG-62.
Note
For availability of additional adapters that allow testing to other
performance standards, different cabling types, or fiber optic
cabling, contact Fluke Networks.