Fluke RUSKA 2456-LEM Specifications

General IconGeneral
Model2456-LEM
Pressure MediaClean, dry, non-corrosive gases
DisplayLCD
Power Supply100-240 VAC, 50/60 Hz
Resolution0.00001 psi
Operating Temperature18 °C to 28 °C
OutputsRS-232

Summary

Chapter 1 Function

General Function

Describes the purpose and capabilities of the RUSKA 2456-LEM monitor.

Safety Information

Highlights warnings and cautions for safe operation and maintenance of the LEM.

Chapter 2 Getting Started

Introduction

Outlines the setup process for PC operation with LEMCal software.

Software Installation

Provides step-by-step instructions for installing the LEMCal software.

Software Setup

Covers initial configuration steps for the LEM software.

Serial Port Setup

Guides on configuring serial port settings for communication.

LEM Addressing

Explains how to view and change the LEM's communication address.

LEMCAL Software

Explains the address setting requirement for LEMCAL software.

Selecting a Pressure Source

Describes how to choose local or remote pressure sources in the software.

Selecting Units

Details how to select preferred units for environmental parameters.

Limits

Introduces setting upper and lower limits for parameters.

Setup

Guides on setting parameter limits, alarms, and copying values.

Password Protection

Introduces password protection for calibration and program exit.

Viewing Real Time Data

Describes how to view live sensor readings on the main screen.

Logging Data

Explains the function of capturing sensor data over time.

Data Logging

Details the data logging screen, module enablement, and intervals.

Addressing

Explains the need for unique addresses for multiple LEMs on a bus.

Chapter 4 Remote Pressure Capture

Remote Pressure Capture

Guides on setting up remote pressure source configuration.

Use with a RUSKA Portable Pressure Gauge 7220 or 6220

Details setup for using external pressure gauges with the LEM.

Chapter 5 Calibration

Span

Details calibration points for pressure sensors.

Temperature

Details calibration points for temperature sensors.

Zeroing

Explains the process of zeroing the sensor for accuracy.

Humidity

Details calibration points for humidity sensors.

Chapter 7 Air Density Calculation

Air Density Available Directly from LEM

Presents the formula and conditions for LEM's direct air density calculation.

Chapter 8 Specifications

Sensors

Lists operating ranges and performance specifications for temperature, pressure, and humidity.

Chapter 9 Remote Commands

Remote Commands

Introduces the two general standards for remote communication.

@ - Set Address

Describes the command to set or change the LEM's address.