Multifunction PV Analyzer
Te s t S e t u p
25
8. Push
to clear or cancel the dc measurement column and return to the blank state.
To make an ac measurement:
1. Connect the test leads to the ac output of the inverter.
2. Connect the Clamp.
Tip: Push
to see a connection diagram.
3. Push
.
4. Push
to hold the ac measurements.
The blue column header indicates that the ac measurements are on hold.
The display shows the Efficiency Factor ratio with a Pass or Fail icon.
5. Push
to save the results to memory.
A confirmation message with ID number shows on the display and then returns to the test
screen.
3-Phase Inverter Performance Check
Measure the dc power, then ac power (L1 + L2 + L3), then compare efficiency.
To m a ke a m e a s u re m e n t :
1. Turn the rotary switch on the PV Analyzer to FUNC./P
AC/DC
.
The display shows power in the blank state and is ready to check the 3-phase power.
2. Push
to toggle between Single Phase and 3 Phase power.
3. Push
to set the Efficiency Factor Limit.
4. Push
.
5. Push
to hold the dc measurements.
The blue column header indicates that the dc measurements are on hold.
6. Push
.
7. Push
to hold the ac-L1 measurements.
The blue column header indicates that the ac-L1 measurements are on hold.
8. Push
.
9. Push
to hold the ac-L2 measurements.
The blue column header indicates that the ac-L2 measurements are on hold.