Do you have a question about the Fluke ScopeMeter 225C and is the answer not in the manual?
Brand | Fluke |
---|---|
Model | ScopeMeter 225C |
Category | Measuring Instruments |
Language | English |
Overview of safety instructions, cautions, and warnings for safe operation and tool maintenance.
Essential safety procedures for correct and safe use by operating and service personnel.
Explanation of caution and warning statements and symbols used to prevent damage or injury.
List and explanation of symbols used on the test tool, user manual, and service manual.
Procedures when safety is likely impaired; refer to qualified technicians for service.
General warnings about exposing live parts and using only specified replacement parts.
Details about the illustrated list of parts, including item number, description, and ordering code.
Instructions for ordering parts by contacting an authorized service center with specific information.
List of all parts included in the final assembly, with item numbers and ordering codes.
Specific list of parts for the Main PCA unit, including item numbers and ordering codes.
Catalog of standard and optional accessories for the ScopeMeter test tool.
Overview of performance tests to ensure proper operation, and required ambient conditions.
List of primary and secondary instruments and accessories needed for verification procedures.
Common instructions for all tests, including power, warm-up, and setup.
Guidance on resetting the tool and navigating menus during performance verification.
Procedure to test the display contrast, brightness, and backlight functionality.
Comprehensive tests for the accuracy and performance of Scope Inputs A and B.
Procedure to test the external trigger level functionality for accurate triggering.
Verification procedures for the multimeter functions, including DC/AC voltage and resistance.
Test to verify the internal probe calibration square wave generator functionality.
Overview of calibration, cycle, number, date, and required equipment for adjustments.
Sequential steps for complete calibration, including partial calibration options.
Steps to enter calibration mode, adjust the date, and select calibration modes.
Procedure to calibrate display darkness, default contrast, and maximum brightness.
Essential warming-up period and pre-calibration steps before final adjustments.
Detailed steps for final calibration, requiring specific input conditions for accuracy.
Instructions on saving calibration results and exiting the maintenance mode.
Procedure for adjusting the VPS200 voltage probes for optimal response.
Overview of disassembly procedures, required tools, and safety precautions.
Step-by-step guide for opening the tool, removing components, and reassembling.