Specications
Model
T90 T110 T130 T150
LEDs
Voltage range 12 V to 690 V ac/dc
• • • •
Resolution
±
12 V, 24 V, 50 V, 120 V,
230 V, 400 V, 690 V
• • • •
Tolerance
Complies with
EN 61243-3:2014
• • • •
Frequency range 0 / 40 Hz to 400 Hz
• • • •
Response time ≤0.5 second
• • • •
Auto power on ≥12 V ac/dc
• • • •
LCD
Voltage range 6 V to 690 V ac/dc
• •
Resolution ±1 V
• •
Tolerance ±(3 % rdg + 5 digits)
• •
Frequency range 0 / 40 Hz to 400 Hz
• •
Response time ≤1 second
• •
Auto power on ≥6 V ac/dc
• •
Voltage detection Automatic
• • • •
Polarity detection Full range
• • • •
Range detection Automatic
• • • •
Internal basic load impedance
Peak current
Maximum 3.5 mA at
690 V 200 kΩ / Is <3.5 mA
(no RCD tripping)
• • • •
Operation time
Duration Time =
30 seconds
• • • •
Recovery time
Recovery Time =
240 seconds
• • • •
Switchable Load ~7 kΩ
• • •
Peak current Is (load) = 150 mA
• • •
RCD tripping I~30 mA @ 230 V
• • •
Continuity Test 0 to 400 kΩ
• • • •
Accuracy nominal resistance +50 %
• • • •
Test current ≤5 µA
• • • •
Single-pole Phase Test 100 V ac to 690 V ac
• • • •
Frequency range
40 Hz to 60 Hz
•
50 Hz to 400 Hz
• • •
Rotary Field Indication
• • •
Voltage range (LEDs)
100 V to 690 V
(phase to earth)
• • •
Frequency range 50 Hz to 60 Hz
• • •
Resistance Measurement 0 Ω to 1999 Ω
•
Resolution 1 Ω
•
Tolerance
±(5 % rdg +10 digits) @
20 °C
•
Temperature coecient ±5 digits / 10 K
•
Test current ≤30 µA
•
Size in mm (HxWxL) 245x64x28 255x78x35
Weight in kg (includes batteries) 0.18 0.27
www.calcert.com sales@calcert.com1.800.544.2843
0
5
10
15
20
25
30