Technical Data
LED voltage range 12...690V AC/DC
LED resolution ±12, 24, 50, 120, 230, 400,
690V
Tolerance complying to DIN VDE 0682,
Part 401
Voltage detection automatic
Acoustic signal (AC voltage) yes
Polarity detection full range
Range detection automatic
Response time <0.1s LED
Frequency range DC, 0...65 Hz
Automatic load (RCD) yes
Internal basic load approx. 2.1 W at 690V
Test current < 3,5 mA
Peak current Is = 0.2 A
Operation time ED (DT) = 30s
Recovery time 240 s
Auto Power On > 12 V AC/DC
Single-pole Phase Test
Voltage range 100...690 V AC
Frequency range 50...65 Hz
Continuity Test
Resistance range 0...200 kΩ
Accuracy RN +50%
Test current 3 µA
Overvoltage protection 690V AC/DC
Power supply 2 x 1.5 V Micro IEC LR03
Power consumption max. 30mA / approx. 250mW
Temperature range -10°C...55°C
Humidity max. 85% relative humidity
Height above sea level up to Tm
Overvoltage class CAT III / 600 V
Degree of contamination2
Type of protection IP54
Safety complying to DIN EN 61243-3, DIN VDE
0682 Part 401 (first DIN VDE
0680 Part 5, EN 61010, IEC
61010)
Weight 130g (incl. batteries)
Dimensions (HxWxD) 210 x 40 x 22 mm
Fluke T50
Technical Data
12