EasyManuals Logo

Fluke T6-1000 Quick Reference Guide

Fluke T6-1000
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HOL
D
3
2
1
5
7
6
200 A
CAT
1000 V
CAT 600 V
4
HOLD
200 A
CAT
1000 V
CAT 600 V
AUTO
SELECT
T6-1000
ELECTRICAL TESTER
5
2
7
3
1
4
6
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated leads
()
PN 4462973
TP1 Probe Set, Flat-Blade PN 648128
Battery Door PN 4944370
Battery Door Screw PN 1618579
Use only specied replacement parts
Quick Reference Guide
Model T6-1000 Model T6-600
Function
Requires
Test Leads
Range Range Resolution Accuracy
[1]
FieldSense
Voltage ac
No 1000 V 600 V 1 V
±(3 % + 3 counts)
45 Hz to 66 Hz
[2] [3]
FieldSense
Current ac
No 200.0 A 200.0 A 0.1 A
±(3 % + 3 counts)
45 Hz to 66 Hz
FieldSense
frequency (Hz)
No 45 Hz to 66 Hz 1 Hz ±(1 % + 2 counts)
[3]
Voltage ac Yes 1000 V 600 V 1 V
±(1.5 % + 2 counts)
45 Hz to 66 Hz
Voltage dc Yes 1000 V 600 V 1 V ±(1 % + 2 counts)
Resistance
Yes 2000 Ω 2000 Ω 1 Ω
±(1 % + 2 counts)Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
[1] Accuracy: ±( [ % of reading] + [number of least signicant digits] ). Accuracy is specied for 1 year after calibration, at
18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are accoupled, RMS responding.
[2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves,
standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specied from 16 V to 100 % of range.
Fork opening 17.8 mm
Temperature
Operating
Storage
-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
2000 m
10 000 m
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coefcient 0.1 x (specied accuracy) / °C for <18°C or >28 °C (<64.4 °F or >82.4 °F)
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
» See “Safety Information”.
Go to www.uke.com to register your product and nd more information, or
download this Quick Reference Guide in other languages.
PN 4897598 September 2017 Rev. 2, 11/17
© 2017 Fluke Corporation. All rights reserved.
Specications are subject to change without notication.
Fork Opening 17.8 mm
Overview
Wire Position
1 Wire Only
Finger Guard
For safe operation, hold the
Tester behind the nger guard.
Display
Model T6-1000
Model T6-600
X Hazardous Voltage ≥30 V
Function Selection/On/Off
Auto Off
15 min
FieldSense Ground Contact
Test Probes/Storage Dock
Symbols
W
WARNING. RISK OF DANGER. Test with fork and FieldSense ground contact.
»
Consult user documentation. Test with fork and ground probe.
Y
Hazardous voltage ≥30 V. Test with probes.
Battery full charge.
FieldSense Measurement: Fluke voltage/current
sensing technique.
Battery low. Replace.
J
Good earth ground connection.
Back light
J
No earth ground connection.
Specications
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566-5655
China: +86-400-921-08365
Anywhere in the world: +1-425-446-5500
● HT6 Belt Holster
● TPAK Hanger
● PRV240FS
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
Contact FlukeUSA:
.Lead Replacement
Accessories
● HT6 ●
Replacement Parts

Other manuals for Fluke T6-1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke T6-1000 and is the answer not in the manual?

Fluke T6-1000 Specifications

General IconGeneral
Control typeButtons, Rotary
Display type-
Housing colorBlack, Grey, Yellow
Jaw width (max)17.8 mm
AC current range- A
AC voltage range- V
Operating altitude0 - 2000 m
Storage temperature (T-T)-30 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Battery typeAA
Number of batteries supported2
Carrying caseYes
Weight and Dimensions IconWeight and Dimensions
Depth43.8 mm
Width61.1 mm
Height259.3 mm
Weight350 g

Related product manuals