To complete the check procedure, always measure a known
voltage before use. If the Tester fails self test or voltage check, it
must not be used and requires service. See “Contacting Fluke”.
Measuring Voltage
To measure voltage, connect the probes to the circuit under test.
The voltage is indicated by the voltage LED stack and beeper (if
enabled). The T+PRO will show the measurement on the LCD for
voltages > 10 V; < 10 V the LCD remains blank. The AC, DC+ and
DC- LEDs will only operate for voltages greater than 24 V. Refer
to Figure 2.
DC Voltage
600 V dc maximum
AC Voltage
600 V rms maximum
45 Hz to 66 Hz
12 V dc
120 V ac
CONTINUITY
120
208
48
24
12
240
277
600
480
CONTINUITY
120
208
48
24
12
240
277
600
480
eqc03f.eps
Figure 2. Measuring Voltage
Note
Maximum measurable voltage is 600 V ac or dc. This will
be indicated on the LED and LCD (T+ PRO).