12
TS42DLX Deluxe Test Set
Users Guide
Hook Flash Duration
When the test set is off-hook, pressing the FLASH key
causes a timed interruption of the loop current to
occur. Some PBX setups or telephone office switches
may use this signal to put a call on hold or to activate
some special function. One flash is generated for each
press of the key.
To change the flash duration value:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the FLASH key.
4
Press a number key to select a hook flash time.
Invalid entries are ignored. The test set gives a
confirmation tone when the entry is accepted.
Pause Duration
The PBX Pause feature lets you insert a delay into
speed dialing numbers. This is required when dialing
out through a system that provides a second dial tone
(such as PBX). Different PBX devices may require
different pause durations to allow enough time for the
second dial tone to be returned. The pause duration
can be programmed.
To change the PBX Pause duration:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the PAUSE key.
4
Press a number key to select a pause time. Invalid
entries are ignored. The test set gives a
confirmation tone when the entry is accepted.
Exclusive Receive-Only Loud Speaker
Under certain usage scenarios (such as hunting for dial
tone), a test set operator may prefer to have the test
set’s speaker remain in Receive-Only mode (muted)
while transitioning in and out of Talk mode. To
accommodate these procedures, the test set may be
configured to operate with the speaker exclusively in a
Receive-Only mode.
To enable/disable Exclusive Receive-Only Loud Speaker
mode:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the MUTE key. The test set gives a
confirmation tone.
Key Hook Flash Time
1 100 ms
2 200 ms
3 300 ms
4 400 ms
5 500 ms
6 600 ms (default)
7 700 ms
8 800 ms
9 900 ms
0 1000 ms
Key Pause Time
1 2 seconds
2 3 seconds
3 4 seconds (default)
4 5 seconds