1
Issue/Rev. 0.6 (2/06)
MNIT001
Turbine Flow Meter
February 2005
Installation/Operation Manual
Table of Contents
Introduction ............................................................................................................................................................. 2
Installation ............................................................................................................................................................... 3
Turbine Flowmeter Maintenance............................................................................................................................. 3
Magnetic Pickups .................................................................................................................................................... 5
Dimensions ............................................................................................................................................................. 7
Magnetic Pickup Enclosures ................................................................................................................................... 8
Turbine Flowmeter Cable Assemblies .................................................................................................................... 9
Repair Parts Kits ................................................................................................................................................... 10
General Specifications .......................................................................................................................................... 11
Turbine Flowmeter Sizing ..................................................................................................................................... 11
3-A Sanitary Meters/Internals................................................................................................................................ 12
Flow Related Formulas ......................................................................................................................................... 13
WH Meter/4200/4300 Manual.................................................................................................................................14
FMC INVALCO ! 2825 W. Washington ! Stephenville, Texas 76401 ! Telephone: 254/968-2181 ! FAX 254/968-5709 ! Toll Free: 800/468-2526
Question and Answer IconNeed help?

Do you have a question about the FMC Technologies INVALCO 64908265 and is the answer not in the manual?

FMC Technologies INVALCO 64908265 Specifications

General IconGeneral
BrandFMC Technologies
ModelINVALCO 64908265
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction to Turbine Flowmeters

Mechanical Installation Requirements

Details on upstream and downstream piping requirements for proper turbine flowmeter installation.

Turbine Flowmeter Installation

Electrical Installation Procedures

Instructions for connecting the magnetic pickup to the flowmeter.

Turbine Meter Maintenance Procedures

Removal of Cartridge Internals

Steps to remove cartridge-type internals from 3/4" to 2" turbine flowmeters.

Turbine Flowmeter Internals Servicing

Older Size Internals Removal

Procedure for removing and replacing internals in older 4-inch and 3-inch flowmeters.

4-Inch Internals Replacement

Steps for installing new internals into 4-inch turbine flowmeters.

Magnetic Pickup Principles

Operation and K-Factor Explanation

Explanation of how magnetic pickups sense flow and generate AC cycles via rotor blades.

Magnetic Pickup Options

Available Pickup Models and Specs

Overview of various magnetic pickup models with specifications and stock numbers.

Flowmeter Dimensions

Physical Size Specifications Table

Table detailing physical dimensions for NPT, Wafer, Grooved, and Flanged flowmeter types.

Magnetic Pickup Enclosures

Protective Enclosure Types

Description of WAK-2, EAK-2, and EAK-2AX-P enclosures for magnetic pickups.

Turbine Flowmeter Cables

Cable Assembly Options and Specs

Details on standard, high-temperature, and pre-amp/RF cable assemblies with part numbers.

Repair Parts and Kits

Tungsten Carbide Bearing Kits

Part numbers for internal components and kits for 'W' Series flowmeters.

Rulon 641 Bearing Kits

Part numbers for internal components and kits for 'WFP' Series flowmeters.

3A Sanitary Bearing Kits

Part numbers for internal components for 'WSP' Series 3A Sanitary flowmeters.

General Specifications

Performance and Material Specs

Details on linearity, repeatability, materials, and temperature ratings.

Turbine Flowmeter Sizing

Flow Range and K-Factor Data

Table showing meter sizes, flow ranges, and nominal K-Factors.

3-A Sanitary Flowmeters

Cleaning and Maintenance Procedures

Guidelines for cleaning and maintaining 3-A sanitary turbine flowmeters.

Flow Calculation Formulas

Unit Conversion and Formulas

Formulas for converting flow rates, pulses, and units of measure.

Model 4200 Rate/Totalizer Overview

Specifications and Features

Technical specifications for the Model 4200 Rate/Totalizer, including display and input.

Quick Setup Guide

Steps for basic setup of the Model 4200 without pulse or analog output.

Model 4200 Operation and Programming

Display Modes and K-Factor Entry

Explanation of display modes and procedure for programming K-Factor for the Model 4200.

Linearization Setup Procedure

Procedure for setting up linearization using multiple K-factors in the Model 4200.

Model 4200 Programming Details

Decimal and Time Scale Settings

Setting decimal positions for rate/total and configuring the time scale.

Scaled Pulse Output Configuration

Enabling and setting the scale for the scaled pulse output.

Model 4200 Advanced Configuration

Password Protection and Battery Replacement

Setting up password protection and instructions for changing the battery.

Input/Output Wiring and Connections

Information on connecting input signals and wiring practices for the Model 4200.

Model 4200 Wiring and Installation

Input and Output Signal Wiring

Diagrams for connecting various input signals and output options.

Operational Warnings and Mounting

Precautions regarding EMF, vibration, and wall mounting procedures.

Intrinsic Safety Compliance

Entity Parameters and Control Drawing

Entity parameters and diagram for hazardous area intrinsic safety connections.

Model 4200 Dimensions

Wall Panel and Direct Mount Options

Dimensional drawings and installation notes for wall panel and direct mounting.