EasyManua.ls Logo

Follett C33985 - Specifications

Follett C33985
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Horizon 1400R/N Ice Machines 5
Specications
Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical – 115/60/1
Maximum fuse 15A
Amperage – 6A
Condensing unit
Single-Phase 3-Phase
Electrical 208-230 V, 60 Hz 208-230 V, 60 Hz
Maximum Circuit HVACR breaker size 30A 25A
Minimum Circuit Ampacity 20.0A 14.0A
Evaporator plumbing
3/8" OD push-in water inlet
3/4" MPT
Notes: 3/4" vented drain line must slope a minimum of 1/4" per ft (6 mm per 30.4 cm run).
Drain to be hard piped and insulated.
Water shut-off recommended within 10 ft (3 m).
Follett recommends installation of Follett water lter system (P/N 00130286) in ice machine inlet water line.
Ambient
Evaporator unit
Air temperature 100 F/38 C max. 50 F/10 C min.
Water temperature 90 F/32 C max. 45 F/7 C min.
Water pressure 70 psi max. (483 kPa) 10 psi min. (69 kPa)
Condenser unit
Air temperature 120 F/49 C max. -20 F/-29 C min.
Refrigeration
3/8" liquid line – insulated
5/8" suction line – insulated
Note: Rack system installations require a reserve capacity of 10,000 BTU/hr at
0 F (-18 C) evaporator temperature.
Evaporator pressure regulator (not supplied) is required.
Weight Ice production
Evaporator unit
190 lb (88 kg)
Condenser unit
Single-phase: 330 lb (150 kg)
3-phase: 320 lb (145 kg)
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1354
614
1293
586
1229
557
1167
529
1107
502
70
21
1333
605
1272
577
1208
548
1146
520
1060
481
80
27
1260
571
1225
556
1190
540
1102
500
1013
460
90
32
1243
564
1208
548
1172
532
1084
492
995
451
100
38
1227
556
1192
541
1157
525
1069
485
980
445
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet Water Temperature F/C
Ambient Air Te mperature F/C
Ice machine capacity/24 hrs.