88 ImagePRO – Multi Format Image Processor Manual # 26-0302000-00 / Revision E
Example: EMAC? (Queries for Ethernet MAC address)
Command:
SBAUD n
Description: Adjust the Serial Baud Rate.
Parameters: n - Serial baud rate: n[0-4] 1200 | 2400 | 9600 | 19200 | 38400
Query:
SBAUD?
Returns the Serial Baud Rate in the format
= n
Example: SBAUD 0 (Adjusts Serial Baud Rate to 1200)
SBAUD? (Queries Serial Baud Rate.)
Command:
SYSAV
Description: Saves the System State into non-volatile memory
Parameters: None
Example: SYSAV (Saves System State.)
Command:
HELP [op]
Description: Displays Command List
Parameters: op[A..Z] optional command
Example: Help (Displays command list)
Help Freez (Displays syntax/parameters for the Freeze command)
Command:
LOADR
Description: Places unit into loader mode. This mode is used to perform field upgrades
Parameters: None.
Example: LOADR (Puts unit into loader mode.)
Command:
RESET
Description: Factory resets the system and sets all settings to factory defaults.
Parameters: None
Example: RESET (Factory reset the ImagePRO)

Table of Contents