P a g e | 15
P4 shows Pre-Heat Settings
Enable Pre-Heat True
Pre-Heat Time 10
Crank Time 3
Figure 6
The feed speed can be
adjusted to suit the
material being chipped see
Figure 6. Turn dial to align
number with pip. Set feed
speed so that the No-
Stress operates as
little as possible, this will
give the highest
throughput. When feeding
Leylandii or leafy material,
set feed roller speed to 4.5.
Emergency Stopping Standard Programme
To stop engine turn off with
ignition key by turning fully
anticlockwise.
1
CONTROL VALVE FEED SPEED
ADJUSTMENT.
POSITION INDICATED BY PIP.
0 = MINIMUM
10 = MAXIMUM