10
OA1
Auxiliary relay operation:
NON
NON
Output disabled (always off)
0-1
Contacts open/close with standby/on mode
LGT
Output enabled for light control
AL0
Contacts open when an alarm condition occurs
AL1
Contacts close when an alarm condition occurs
(Relay contacts open when in standby mode)
INP
Temperature sensor(s) type:
SN4
SN4
10k NTC type thermistor (red writing)
ST1
1k PTC type thermistor (Black Writing)
OS1
-12.5...12.5°C
Air temperature probe (T1) offset.
0
T2
T2 Probe function:
NON
NON
T2 Probe disabled
EPO
Evaporator temperature monitoring
CND
Condenser temperature monitoring
OS2
-12.5…12.5°C
T2 probe temperature offset
0
TLD
1 … 30min
Delay for min (TLO) and max. (THI) temperature logging
10
SIM
0 … 100
Display Slowdown
5
ADR
1… 255
FD2-10 address for PC communication
1