Minimum evaporator fan stop (following door
opening etc.).
Evaporator fan mode during thermostatic
control.
Te-Ta difference for fans to turn off after
compressor stopped. (Only if T2 = EPO and
FCM = TMP).
Temperature differential for evaporator fan
restart. (Only if T2 = EPO and FCM = TMP).
Fan stop delay after compressor stop.
Timed fan stop following FT1. (With FT2 = 0
the fans remain on all the time).
Timed fan run following FT2. (With FT3 = 0 &
FT2 > 0 the fans remain off all the time).
Alarm threshold configuration.
Low temperature alarm threshold.
High temperature alarm threshold.
Low temperature alarm differential. (With
ALR = 0 the low temperature alarm is
excluded).
High temperature alarm differential. (With
AHR = 0 the low temperature alarm is
excluded).
Delay before alarm temperature warning.
Delay before door open alarm warning.
Operation in case of high condenser alarm
(T2 = CND).
Condenser alarm temperature (T2 = CND).
Condenser cleaning period. (With ACC = 0
condenser cleaning is disabled).
Switchover method to second parameter set.
Minimum limit for IISP setting.
Maximum limit for IISP setting.
Temperature setpoint to be achieved in
'Mode 2'.
Off / On thermostat differential in 'Mode 2'.
Evaporator fan mode during 'Mode 2'
thermostatic control.