16
246
HDS
1
…..
5
Controller sensitivity for switch over between
'Modes' 1 and 2. (1 = minimum, 5 =
maximum).
3
3
3
3
222
IIDF
0
hours
…..
99
hours
Time interval between defrosts in 'Mode 2'.
6
6
6
6
268.7
SB
NO
…..
YES
Standby button operation.
YES
YES
YES
YES
268.0
DS
NO
…..
YES
Door switch operation (switch made when
door closed).
NO
NO
NO
NO
251
DI2
NON
IISM, RDS,
DS2
HPS
Configurable digital input operation.
NON
NON
NON
NON
248
LSM
NON
DOR, NDR
MAN
Light control mode.
NON
NON
NON
NON
249
OA1
NON
LGT, AL0,
AL1
0-1
Auxiliary relay operation.
0-1
0-1
0-1
0-1
268.2
INP
ST1
…..
SN4
Temperature sensor(s) type.
SN4
SN4
SN4
SN4
256
OS1
-
12.5
o
C
…..
12.5
o
C
Air temperature probe (T1) offset.
0
0
0
0
250
T2
NON
EVP
CND
T2 probe function.
NON
NON
NON
NON
251
OS2
-
12.5
o
C
…..
12.5
o
C
T2 probe temperature offset.
0
0
0
0
252
TLD
1 min
…..
30 min
Delay for min. (TLO) and max. (THI)
temperature logging.
10
10
10
10
254
SIM
0
…..
100
Display slowdown.
5
5
5
5
255
ADR
1
…..
255
FD2-10 address for PC communication
1
1
1
1
Parameters ALA and AHA will not be visible when ATM is set at REL.
Parameters ALR and AHR will not be visible if ATM is changed to ABS.