Foster Prep Station
with
FD2-10 Controller
Service Manual
Issued August 2010
ISO 14001
ISO 9001

Questions and Answers

  • C
    Carol McgrathSep 15, 2025
    Why is there no illumination in my Foster FD2-10 glass door model?
    • E
      ebonyphillipsSep 16, 2025
      If there is no illumination in your Foster Controller glass door model, it could be due to: * The light switch being in the “off” position. Press the light switch to the “on” position. * False contact on the light switch, the fluorescent tube, or the ballast. Inspect all connections. * A damaged light switch, ballast, and/or fluorescent tube. Replace the damaged component.
  • M
    Margaret ThorntonNov 18, 2025
    Why is my Foster FD2-10 compressor not starting?
    • K
      Kenneth MaddenNov 18, 2025
      There are several reasons why the compressor in your Foster Controller might not start. It could be due to: * No voltage in the socket. Use a voltmeter to check. * Cut electrical conductors or wires. Use an ohmmeter to check for continuity. * A defective electrical component such as the thermostat, relay, or thermal protector. Replace the defective component. * The compressor motor having an open or shorted winding. Measure the ohmic resistance of the main and auxiliary windings using an ohmmeter and compare with correct values. * A stuck compressor. Change the compressor. * Open temperature control contacts. Repair or replace the contacts. * Incorrect wiring. Check the wiring diagram and correct it. * A blown fuse or tripped circuit breaker. Replace the fuse or reset the ...
  • V
    Valerie HarrisNov 20, 2025
    What to do if my Foster Controller temperature is not cold enough?
    • D
      donaldwhiteNov 20, 2025
      If the temperature in your Foster Controller isn't cold enough, consider these possibilities: * The controller is set at a very warm position. Adjust to a colder setting. * The condenser is dirty. Clean the condenser. * The refrigerator has been placed at an inadequate location. The unit must not be near stoves, walls exposed to the sun, or places lacking sufficient airflow. * The compressor is inefficient or there is high pressure due to air in the system. If there is air, purge and recharge. * The evaporator coil is iced up. Check the temperature control, refrigerant charge, and defrost mechanism. Remove all ice manually and start over. * There is a restriction in the system. Locate the exact point of restriction and correct it. * The refrigerator has been used improperly....

Summary

Health & Safety Information

Environmental and Disposal Policy

Environmental Management Policy

Foster Refrigerator's commitment to managing environmental impacts and contractor compliance.

Disposal Requirements

Guidelines for the proper disposal of refrigerators and hazardous components.

Foster Prep Station Features

Product Description and Specifications

Overview of cabinet construction, capacity, temperature ranges, and physical dimensions.

Controller Interface and Operation

Details on the FD2-10 controller, display, buttons, indicators, and basic operation.

Controller User Functions

Starting Sequences and Testing

Procedures for initiating normal operation, test sequences, and cancellation.

Menu Navigation and Set Point Adjustment

How to access information menus and modify temperature set points.

Advanced Controller Settings

Standby Mode and Parameter Set Switching

Functions for standby operation and selecting between different parameter groups.

Defrost Control

Explanation of automatic and manual defrost, defrost types, and cycle resumption.

Technical Data and Wiring

Wiring Diagram for Defrost Synchronization

Diagram illustrating wiring for defrost control and controller connectivity.

Accessing Configuration Parameters

Method for entering and navigating the controller's parameter configuration menu.

Controller Parameter Values

Default Parameter Settings for FD2-10

Comprehensive table of default parameter values for the FD2-10 controller.

Component Arrangements and Diagrams

Cabinet General Arrangement

Illustration of the overall physical layout of the prep station cabinet.

Evaporator Assembly Diagram

Detailed diagram of the internal evaporator unit, including fans and cooling elements.

Condensing Unit Configurations

Condensing Unit Arrangement for FPS2 HR;FPS3 HR

Visual representation of the condensing unit assembly for specific models.

Condensing Unit Arrangement for FPS4 HR;FPS5 HR

Visual representation of the condensing unit assembly for other specific models.

Detailed Technical Specifications

Technical Data Table for Prep Stations

A table listing key technical data like gas type, charge, compressor, voltage, and power for each model.

FD2-10 Controller Parameter Details

Parameter Values for Foster FD2-10 Controller

Extensive tables showing parameter ranges and default values for various controller functions.

System Wiring and Probes

Prep Station Wiring Diagram

Electrical schematic illustrating component connections and the controller's wiring layout.

Air and Evaporator Probe Specifications

Diagrams and identifying information for the T1 (air) and T2 (evaporator) temperature probes.

Troubleshooting Common Issues

Compressor and Temperature Problems

Solutions for compressor starting failures and issues with the unit being too cold or warm.

Operational and Environmental Issues

Troubleshooting for noise, electrical faults, condensation, and door sealing problems.

Foster FD2-10 Specifications

General IconGeneral
BrandFoster
ModelFD2-10
CategoryController
LanguageEnglish