Incorrect grounding can cause physical injury, death or equipment malfunc-
tion and increase electromagnetic interference.
Make sure that grounding conductor is adequately sized as required by
safety regulations.
Do not connect the ground terminals of the unit in series in case of a multi-
ple installation. This product can cause current with a DC component. Where a
residual current operated protective (RCD) or monitoring (RCM) device is used
for protection in case of direct or indirect contact, only an RCD or RCM of type B
is allowed on the supply side of this product.
For United Kingdom
The installation that connects the equipment to the supply terminals shall
comply with the requirements of BS 7671.
Electrical installation of PV system shall comply with requirements of BS 7671
and IEC 60364-7-712.
No protection settings can be altered.
User shall ensure that equipment is so installed, designed and operated to
maintain at all times compliance with the requirements of ESQCR22(1)(a).
For Australia and New Zealand
Electrical installation and maintenance shall be conducted by licensed
electrician and shall comply with Australia National Wiring Rules.
2.3
Explanation of Symbols
This section gives an explanation of all the symbols shown on the inverter and
on the type label.