7.
Troubleshooting
7.1
Troubleshooting
This section contains information and procedures for solving possible problems
with the FoxESS inverters, and provides you with troubleshooting tips to identify
and solve most problems that can occur with the FoxESS inverters.
7.1.1
Check the fault message on the System Control Panel or a Fault code on
the inverter information panel. If a message is displayed, record it before doing
anything further.
7.1.2
Attempt the solution indicated in table below.
7.1.3
If your inverter information panel is not displaying a fault light, check the
following list to make sure that the present state of the installation allows
proper operation of the unit:
(1)
Is the inverter located in a clean, dry, adequately ventilated place?
(2)
Have the DC input breakers opened?
(3)
Are the cables adequately sized?
(4)
Are the input and output connections and wiring in good condition?
(5)
Are the configuration settings correct for your particular installation?
(6)
Are the display panel and the communications cable properly connected
and undamaged?
Contact FoxESS Customer Service for further assistance.
Please be prepared to describe details of your system installation and provide
the model and serial number of the unit
Grid Volt Fault
Grid Freq Fault
1.
Wait for one minute, grid may go back to normal working state.
2.
MakE sure that grid voltage and frequency complies with standards. 3
Or, please seek for help from us.