Technical Data
4.1 DC input
Model
E3000
E3600
E4600 E5000 E6000
Max. recommended DC power [W]
3900
4680
F4600
5980
F5000
6500
F6000
7800
Max. DC voltage[V]
600
600
600
600
600
Nominal DC operating voltage[V]
360
360
360
360
360
MPPT voltage range [V]
80-550
80-550
80-550
80-550
80-550
MPPT voltage range @ full load [V]
130 -550
150 -550
200 -550
210 -550
250 -550
Max. input current [A]
12.5/12.5
12.5/12.5
12.5/12.5
12.5/12.5
12.5/12.5
Max. short circuit current [A]
15/15
15/15
15/15
15/15
15/15
Start output voltage [V]
120
120
120
120
120
No. of MPP trackers
2
2
2
2
2
Strings per MPP tracker
1
1
1
1
1
DC disconnection switch
Optional
4.2 AC output
Model
E3000
E3600
E4600
E5000
E6000
Displacement power factor
Feed in phase
Over voltage category
1 (Adjustable from 0.8 leading to 0.8 lagging)
single-phase
PV:OVC
II
Mains: OVC
III
Rated output power [W]
3000
3600
F4600
4600
F5000
5000
F6000
6000
Max.apparent AC power [VA]
3300
3960
5060
5500
6000
Rated grid voltage and range [V]
220/230/240
Rated AC frequency and range [Hz]
50 /60
AC nominal current [A]
13.0
15.7
20.0
21.7
26.1
Max. output fault current [A]
14.3
17.2
22.0
23.9
26.1
Max. inverter backfeed current to
the array(mA)
0
THD
<3%