Note!
Grounding the PV modules
The E/F series are transformerless inverters. That is why they have
no
galvanic separation. Do not ground the DC circuits of the PV
modules connected to the E/F series. Only ground the mounting
frame of the PV modules. If you connect grounded PV
modules to the E/F series, the error message "IsolationFault" will
appear.
Comply with the local requirements for grounding the PV
modules and the PV generator. FoxESS recommends connect-
ing the generator frame and other electrically conductive
surfaces in a manner which ensures continuous conduction and
ground these in order to have optimal protection of system and
persons.
Caution!
The temperature of some parts of the inverter may exceed 60℃
during operation. To avoid being burnt, do not touch the
inverter during operation. Let it cool before touching it.
•
Prior to the application, please read this section carefully to ensure correct
and safe application. Please keep the user manual properly.
•
Use only attachments recommended or sold by FoxESS. To do otherwise may
result in a risk of fire, electric shock, or injury to person.
•
Make sure that existing wiring is in good condition and that wire is not
undersized.
•
Do not disassemble any parts of inverter which are not mentioned in installa-
tion guide. It contains no user-serviceable parts. See the warranty policy or
instructions
on obtaining service. Attempting to service the E/F Series inverter yourself may
result in a risk of electric shock or fire and will void your warranty.