– 33 –
EN
MESSAGES AND MALFUNCTIONS
Resetting boiler faults
If the boiler goes to ‚fault‘, you can try to remedy the
fault by resetting the boiler.
9 The FAULT RESET function is activated by
pressing the ON/STANDBY button for approx.
3 seconds while the fault is displayed.
9 The light in the button goes out to confirm the
reset.
9 The boiler restarts in STANDBY mode. The button
has a steady white light.
9 The ECO function is deactivated after the reset.
CAUTION: If you cannot remedy a fault or
defect yourself, please contact Franke or your
installer. Switch off the boiler by removing the plug
from the wall plug socket.
Boiler messages
Boiler status indicator LED
LED colour LED action Boiler mode Description
White Steady STANDBY Heating of boiler water switched off
White Steady STANDBY Frost protection active
White Steady STANDBY Legionella prevention active
Red Steady ON Water temperature > 103°C
Orange Steady ON 45°C < Water temperature < 103°C
Dark Blue Steady ON Water temperature < 45 °C
Yellow Steady ON Boiling dry test
Green Steady ECO Night period active
Pink Steady ECO Water temperature > 103°C
Violet Steady ECO 45°C < Water temperature < 103°C
Light blue Steady ECO Water temperature < 45 °C