CAUTION: During a fault, the function of the boiler is switched off.
5l Boiler malfunction LED
LED colour LED action Description
Red 1 second on / 1 second off Hardware fault
Red 4 x 0.5 second on / 2 seconds off Software fault
Red/white 1 second red / 1 second white Hardware fault - sensor is defective
Red/yellow 1 second red / 1 second yellow Boiled selection fault - wrong pcb
Red/blue 1 second red / 1 second blue No water pressure
Red/orange 1 second red / 1 second orange Maximum protection has tripped - boiler too hot (*)
Red/green 1 second red / 1 second green Boiler is upside down or installed upright
*) Switch off the boiler and contact Franke.
10l Boiler malfunction LED
LED colour LED action Description
Red Flashes 1x and 2 seconds off Hardware fault
Red Flashes 2x and 2 seconds off Hardware fault - sensor is defective
Red Flashes 3x and 2 seconds off Boiled selection fault - wrong pcb
Red Flashes 4x and 2 seconds off Boiler is upside down or installed upright
Yellow Flashes 1x and 2 seconds off Boiler dry - no water in the boiler
Yellow Flashes 2x and 2 seconds off Maximum protection has tripped - boiler too hot (*)
Yellow Flashes 3x and 2 seconds off
Water filter cartridge is finished and must be replaced
immediately. Heating of the boiler is switched off
*) Switch off the boiler and contact Franke.
Tap messages
LED colour LED action
Function Description
Blue / red Alternately
Protection active, the
first water dispensed
can be hot.
Press the selector knob twice briefly while flashing
to cancel the protection function or press and hold
selector knob (3 sec.) until the water starts to flow.
Orange
Pulsating/Heartbeat
Filter cartridge is
almost consumed
(90%)
Filter cartridge is almost finished and must be
replaced shortly.
Orange
Continuous
Filter cartridge has
been used (100%)
must be replaced
immediately.
Filter cartridge is almost finished and must be
replaced shortly.
Orange
Continuous
Filter cartridge has
been used (110%)
blockade of boiling and
filtered water
Filter cartridge is finished and must be
replaced immediately.
Orange Blinking
No valve has been
detected / a valve is
defective
Check the cabling and or the valve.