363
600
32.5
220
235
Ø120 d1
min 50
32.5
180
min 50
min 200
Installation and technical data
Page 15
Add-on units
Installation dimensions for add-on units
Distance to the wall must be at least 50 mm. Clearance above the
machine must be at least 200 mm.
Adjustable feet (optional) can be used to compensate for unevenness
or height differences.
If optional add-on units are installed, 300 mm are required per add-
on unit.
Observe the connection requirements of the add-on units.
Grommet holeTop viewSide viewFront view
Refrigeration unit dimensions (as an example)
30 mm foot 520 mm + 30 mm = 550 mm
40 mm foot 520 mm + 40 mm = 560 mm
70 mm foot 520 mm + 70 mm = 590 mm
100 mm foot 520 mm + 100 mm = 620 mm
Adjustable feet (optional)
Capacity up to 120 cups (depending on cup size)
Electrical connection 200 - 240 V1L N PE300 W50/60 Hz Fuse: 10 A
Electric cable 2000 mm
Weight 17 kg
Width 300 mm
Depth 580 mm
Height 545 mm
Milk container 10 liters or 2 x 4.5 liters
Electrical connection 200 - 240 V1L N PE100 W50/60 Hz Fuse: 10 A
Electric cable 2000 mm
Ambient conditions Humidity: max. 80 %
Ambient temperature: 5 - 32 °C
Weight approx. 24 kg
Width 300 mm
Depth 580 mm
Height 545 mm
Technical data for the cup warmer
Technical data for the refrigeration unit